With the EcoSpace Toolbox, you can obtain customized CAD Drawings, SketchUp Models and 3-Part CSI Building Specifications for the EcoSpace Elevator product. All drawings are intended for preliminary planning.

Country
Please select a Country.
The following project information is optional but recommended (shown on CAD title block).
Project Name
Building Location (City)
Requester Name
 
Design Documents
Which design documents do you require?
CAD Drawing
BIM Object
Specification
Please select the Dimensions Format
MetricImperial*
Continue »
These selections are required to generate a CAD drawing.
Capacity
NBC Stretcher Requirements for Passenger Shaped Elevators

National Building Code 610 mm x 2010 mm Stretcher

1134 Capacity
  • Left or Right Opening Door


1814 Capacity
  • Center Opening Door

Capacity
907 kg1134 kg1361 kg1588 kg1814 kg1814 kg Service shape2041 kg Service shape2268 kg Service shape2000 lbs2500 lbs3000 lbs3500 lbs4000 lbs4000 lbs Service shape4500 lbs Service shape5000 lbs Service shape*
 
Quantity
Available up to Four Car groups and 20 openings. For applications and features other than those shown here, please contact your local KONE sales professional.
Quantity
12*
 
Speed
0.75 m/s1.00 m/s1.78 m/s150 fpm200 fpm350 fpm*
 
Power Supply
208240480575*
 
Seismic
In areas regulated by the Uniform Building Code (UBC), zones 0-1 are classified as non-seismic and zones 2-4 are seismic.

In areas regulated by the International Building Code (IBC), there are 3 parameters related to building design that affect the determination if an elevator requires a seismic design: Seismic Design Category, Design Spectral Response at a short period – SDS, and elevator component Importance Factor – IP.

Please contact your local KONE sales professional for further assistance with seismic elevator design requirements.
Seismic
Non-SeismicSeismic*
 
Landings
Total Number
 
Openings And Travel
oepnings and travel info
Openings & Travel
Set all floors tomm
* Clicking 'Update All' will change existing sizes for all floors.
* Change individual floor heights below.


LandingOpeningsFloor Height
Landing 15:Front Back
Landing 14:Front Back
Landing 13:Front Back
Landing 12:Front Back
Landing 11:Front Back
Landing 10:Front Back
Landing 9:Front Back
Landing 8:Front Back
Landing 7:Front Back
Landing 6:Front Back
Landing 5:Front Back
Landing 4:Front Back
Landing 3:Front Back
Landing 2:Front Back
Landing 1:Front Back
TOTAL TRAVEL:
The total travel must be 10058 mm or greater for a speed of 1.78 m/s
The maximum total Travel allowed is 25900 mm
Total travel is the distance from floor/sill of first landing to f/s of top landing.
Floor Height Criteria:
  • Minimum Floor Height: 2540mm (376mm-508mm for front/rear non-opposed depending on speed)
  • Maximum Floor Height: 7315mm (5690mm for Seismic)
  • Maximum Travel: 25m-45.7m (depending on speed)

Default: Landings x 3048mm (2772mm for 10+ Landings)
Set all floors toft' in"
* Clicking 'Update All' will change existing sizes for all floors.
* Change individual floor heights below.


LandingOpeningsFloor Height
Landing 15:Front Back
ft' in"
Landing 14:Front Back
ft' in"
Landing 13:Front Back
ft' in"
Landing 12:Front Back
ft' in"
Landing 11:Front Back
ft' in"
Landing 10:Front Back
ft' in"
Landing 9:Front Back
ft' in"
Landing 8:Front Back
ft' in"
Landing 7:Front Back
ft' in"
Landing 6:Front Back
ft' in"
Landing 5:Front Back
ft' in"
Landing 4:Front Back
ft' in"
Landing 3:Front Back
ft' in"
Landing 2:Front Back
ft' in"
Landing 1:Front Back
TOTAL TRAVEL:'-"
The total travel must be 33' or greater for a speed of 350 fpm
The maximum total Travel allowed is 85'-0"
Total travel is the distance from floor/sill of first landing to f/s of top landing.
Floor Height Criteria:
  • Minimum Floor Height: 8'-4" (14.8-20" for front/rear non-opposed depending on speed)
  • Maximum Floor Height: 24' (18'-8" for Seismic)
  • Maximum Travel: 85'-150' (depending on speed)

Default: Landings x 10ft (9' for 10+ Landings)
 
Elevator Configuration
Car Height
Clear Overhead mm (Max. 4877 mm)
Door Height
Pit Depth
* A 1219 mm pit may be feasible in special circumstances. Please contact a KONE representative for more information
Clear Overhead must be less than 4877 mm
Clear Overhead must be at least 1524 mm greater then the Car Height
Clear Overhead must be at least 1549 mm greater then the Car Height
Clear Overhead must be at least 1651 mm greater then the Car Height
Clear Overhead must be at least 4343 mm for integrated controller configurations
Car Height
Clear Overhead ft'in" (Max. 16 ft)
Door Height
Pit Depth
* A 4'-0" pit may be feasible in special circumstances. Please contact a KONE representative for more information
Clear Overhead must be less than 16ft
Clear Overhead must be at least 60 inches greater then the Car Height
Clear Overhead must be at least 62 inches greater then the Car Height
Clear Overhead must be at least 65 inches greater then the Car Height
Clear Overhead must be at least 171 inches for integrated controller configurations
 
Door Type
 
Control Location
Verify Control location selection is permissible with local code authority or contact your local KONE sales professional.

Integrated Control - The smallest controller option located inside the front hoistway wall at the top landing.
Integrated Control View
Adjacent Room – Cost efficient room adjacent to the hoistway at the top landing.
Adjacent Room View
Remote Closet – The smallest and a very versatile controller option which enables the controller to be positioned up to 43 wire metres away from the top landing. Please note that electrical code requires min. 1067 mm of clear space in front of door opening.
Remote Closet View
Remote Room – Versatile controller option which can be positioned up to 43 wire metres away from the top landing.
Remote Room View
Control Location
Integrated Control (Must be located at TOP FRONT LANDING)Adjacent RoomRemote ClosetRemote Room*
 
Emergency Battery Power Supply
When the main line power is lost for longer than 5 seconds the emergency battery power supply provides power automatically to the elevator controller. The elevator will rise or lower to the first available landing, open the doors, and shut down. The elevator will return to service upon the return of normal main line power.
Emergency Battery Power Supply
Emergency Battery Power Supply
 
 
Continue »
 
Entrance Finish
Brushed Stainless SteelPainted Finish*
 
Car Wall Material
Brushed Stainless SteelLaminateLaminate SeriesVintage SeriesStainless SeriesGlass SeriesScottish Quad Rigidized Stainless Steel*
 
Car Protection Pads
Include Car Protection Pads
 
Ceiling
Standard Translucent Panels - LF-1Round Diffusers in Stainless Frame - LF-2Fluorescent Drop Ceiling - LF-94Round LED Down Light Drop Ceiling - LF-88Square LED Down Light Drop Ceiling - LF-97Rectangle LED Down Light Drop Ceiling - LF-98*
 
Handrail Type
Round tube brushed aluminum - 1.5 in.Custom Round - satin stainless steel - 2 in.Custom Flat - satin stainless steel - 1.5 in. wideCustom Flat - satin stainless steel - 2 in. wideCustom Flat - satin stainless steel - 3 in. wideCustom Flat - satin stainless steel - 4 in. wide*
 
Handrail Location
Side Walls - Front and Back openings onlyBack Wall - Front opening onlyBack Wall and Side Walls - Front opening only*
 
Signal Devices and Fixtures
KSS 570 Flush Return with Amber, Dot Matrix DisplayKSS 570 Flush Return with White, Dot Matrix DisplayKSS 570 Flush Return with Blue, Dot Matrix DisplayKSS140 Vandal Resistant Signalization Amber, Dot Matrix*
 
Additional features of COP
Firefighters Phase 2 Instructions In Car
Landing Pass Signal
 
Lantern & Chime Location
In CarAt Each Landing*
 
Combo Hall Position Indicator
 
 
Continue »
 
Maintenance Service
12 Months9 Months6 Months3 Months*
 
Call Back Service
Regular time call back service: Maintenance service to be performed during regular working hours of regular working days and shall include regular time call back service.

Emergency 24-hour call back service: Maintenance service to be performed during regular working hours of regular working days and shall include emergency 24-hour call back service.
Call Back Service
Regular time call back serviceEmergency 24-hour call back service*
 
Additional Power Supply
Automatic Standby Power with Building Generator - When the main line power is lost and stand-by power becomes available from the building generator all elevators are recalled one at a time to a predetermined floor, open the doors, and shut down.

Emergency Battery Power Supply – When the main line power is lost for longer than 5 seconds the emergency battery power supply provides power automatically to the elevator controller. The elevator will rise or lower to the first available landing, open the doors, and shut down. The elevator will return to service upon the return of normal main line power.
Additional Power Supply
NoneAutomatic Standby Power with Emergency Building GeneratorEmergency Battery Power Supply*
 
Additional Options
Independent Service
Hoistway Access Bottom Landing
Hoistway Access Top Landing
Car Secure Access
Provision for Card Reader
Emergency Hospital Service
Provision for CCTV
Intercom Provisions
 
 
Continue »
 
Stop Go
Congratulations! You are now ready to generate your documents.
Please fix the following errors before generating your documents.

Remember, the architectural toolbox is intended for planning purposes only. All CAD drawings, building specifications and 3D models produced using the architectural toolbox are not final construction documents and cannot be used for building or construction purposes. In case you would like to receive a drawing for construction purposes please contact your local KONE representative.